Set Appliance State:
Mains Power Off
Gas Off
DHW Demand
DHW Selector in Maximum (+) position
CH Selector in Minimum (-) position
ON/OFF Switch in ON position
DHW Selector in Maximum (+) position
CH Selector in Minimum (-) position
ON/OFF Switch in ON position
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Allow the burner to ignite and, after approximately 3 to 4 seconds,
measure the voltage across the connections of the modulating solenoid.
Expected voltage is approximately 16 Volts DC.
measure the voltage across the connections of the modulating solenoid.
Expected voltage is approximately 16 Volts DC.

Isolate as per TOPs P4
and refit as necessary