Set Appliance State:

Mains Power Off
Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect plug from DHW sensor (purple and grey leads)

Measurement:

Measure resistance across the exposed terminals of the sensor.
The resistance measured will depend on the boiler temperature.
The hotter the boiler, the lower the resistance.
Temp °CResistance in kOhms
20 - 308 to 16
30 - 40 6 to 10
40 - 503.9 to 8
50 - 602.5 to 5.5
60 - 701.5 to 3.0
Refit leads after test.