Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector M4 from the PCB
Measurement:
Test 1:
Measure the resistance between the two outer wires on connector M4.
Resistance should be approximately 225 Ohms.
Note: If appliance fitted with an ErP pump resistance should be significantly higher
Test 2:
Measure the resistance between the outer brown wire on M4 to a suitable earth point.
Resistance should be greater than 1M Ohm.
Measure the resistance between the two outer wires on connector M4.
Resistance should be approximately 225 Ohms.
Note: If appliance fitted with an ErP pump resistance should be significantly higher
Test 2:
Measure the resistance between the outer brown wire on M4 to a suitable earth point.
Resistance should be greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary