Set Appliance State:
Mains Power Off
CH Demand
CH temperature control to maximum
DHW temperature control to minimum
CH temperature control to maximum
DHW temperature control to minimum
Remove control box cover
ON/OFF switch in the ON position
ON/OFF switch in the ON position
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Measure DC voltage across the terminals 3 and 5 on the Timer.
Expect approx. 0Vdc across the terminals.
Expect approx. 0Vdc across the terminals.

Isolate as per TOPs P4
and refit as necessary