Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect connector CN8 from the PCB

Measurement:

Test 1:
Measure the resistance between the brown wire and the blue wire next to it on CN8.
Resistance should be approximately 225 Ohms.
Note: If appliance fitted with an ErP pump resistance should be significantly higher
Test 2:
Measure the resistance between the brown wire on CN8 to a suitable earth point.
Resistance should be greater than 1M Ohm.