Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Main switch in ON position
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
With the pilot alight (keep Gas Control Valve Knob depressed) measure the voltage on both terminals of Cut Off Thermostat. Voltage measured should be greater than 8mV DC in both cases.

Isolate as per TOPs P4
and refit as necessary