Set Appliance State:
Mains Power Off
Turn Hot Water Tap On
Selector switch in OFF position
CH temperature selector to minimum
DHW temperature selector to maximum
CH temperature selector to minimum
DHW temperature selector to maximum
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Turn the selector switch to the water heating position.
With a flow rate of approximately 9.7 l/min (2.1gals/min 1pint in approximately 3.5 seconds),
is there a temperature rise of 35 deg C?
Is the operation satisfactory?
With a flow rate of approximately 9.7 l/min (2.1gals/min 1pint in approximately 3.5 seconds),
is there a temperature rise of 35 deg C?
Is the operation satisfactory?