Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove the wires from the spark generator
noting their locations

Measurement:

Measure the resistance between the two terminals on the spark generator.
Expect a resistance of approximately 1.9Mohm or greater.
Is the resistance measured as expected?