Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the wires from the spark generator
noting their locations
noting their locations
Measurement:
Measure the resistance between the two terminals on the spark generator.
Expect a resistance of approximately 1.9Mohm or greater.
Is the resistance measured as expected?
Expect a resistance of approximately 1.9Mohm or greater.
Is the resistance measured as expected?

Isolate as per TOPs P4
and refit as necessary