Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove pump cover
Remove wires from pump terminals
Remove wires from pump terminals
Measurement:
Test 1:
Measure the resistance between the live and neutral connections to the pump assembly.
Expect a resistance of approximately 225 ohms.
Test 2:
Measure between one of the pump connections to a suitable earth.
Expect a resistance of 1Mohm or greater.
Are the resistances measured as expected?
Measure the resistance between the live and neutral connections to the pump assembly.
Expect a resistance of approximately 225 ohms.
Test 2:
Measure between one of the pump connections to a suitable earth.
Expect a resistance of 1Mohm or greater.
Are the resistances measured as expected?

Isolate as per TOPs P4
and refit as necessary