Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector X2 from the PCB
Measurement:
Test 1.
Measure for resistance across pins 2 (black) and 3 (blue) of connector X2.
Expected resistance 1Mohm or greater.
Test 2.
Measure for resistance across pin 2 (black) and a suitable earth connection.
Expected resistance greater than 1Mohm.
Measure for resistance across pins 2 (black) and 3 (blue) of connector X2.
Expected resistance 1Mohm or greater.
Test 2.
Measure for resistance across pin 2 (black) and a suitable earth connection.
Expected resistance greater than 1Mohm.

Isolate as per TOPs P4
and refit as necessary