Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Ensure No demand is present
Remove the speed control electrical connector to pump & make safe
Ensure No demand is present
Remove the speed control electrical connector to pump & make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Reset boiler if required.
Test 1.
Measure for DC voltage across pin 2 of connector X12 & a suitable earth connection.
Expected voltage approximately 15.0 Vdc.
Test 2.
Turn Hot Water Tap On & repeat test 1.
Expected voltage approximately 1.5 Vdc.
Test 1.
Measure for DC voltage across pin 2 of connector X12 & a suitable earth connection.
Expected voltage approximately 15.0 Vdc.
Test 2.
Turn Hot Water Tap On & repeat test 1.
Expected voltage approximately 1.5 Vdc.

Isolate as per TOPs P4
and refit as necessary