Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to pump electrical connections at pump
Remove the wires from the pump electrical connections
Remove the wires from the pump electrical connections
Measurement:
Test 1.
Measure for resistance across live & neutral terminals of the pump.
Expected resistance 160 Ohms or greater.
Test 2.
Measure for resistance across live & earth terminals of the pump.
Expected resistance greater than 1Mohm.
Note.
1. Ensure a good connection is made or misdiagnosis will occur.
2. Resistances may register as O.L on the multimeter, this would indicate a resistance greater than 1Mohm.
Measure for resistance across live & neutral terminals of the pump.
Expected resistance 160 Ohms or greater.
Test 2.
Measure for resistance across live & earth terminals of the pump.
Expected resistance greater than 1Mohm.
Note.
1. Ensure a good connection is made or misdiagnosis will occur.
2. Resistances may register as O.L on the multimeter, this would indicate a resistance greater than 1Mohm.

Isolate as per TOPs P4
and refit as necessary