Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the retaining pin which holds the diverter motor in place, rest the motor on the boiler chassis in front of the diverter valve with the spindle facing upwards
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Press reset to cancel purge cycle countdown.
DHW demand.
Check the position of the spindle, it should extend fully for DHW operation.
Note:
The spindle rests in this position so may already be fully extended.
DHW demand.
Check the position of the spindle, it should extend fully for DHW operation.
Note:
The spindle rests in this position so may already be fully extended.
Isolate as per TOPs P4
and refit as necessary