Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gas Off
DHW Demand
Disconnect spark electrode lead from the igniter unit
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Press reset to cancel purge cycle countdown.
STAND CLEAR OF THE APPLIANCE.
Allow fan to run and ignition sequence to commence.
Can sparking be seen between the spade terminal on the igniter and the heat exchanger support bracket to the left?
STAND CLEAR OF THE APPLIANCE.
Allow fan to run and ignition sequence to commence.
Can sparking be seen between the spade terminal on the igniter and the heat exchanger support bracket to the left?
Isolate as per TOPs P4
and refit as necessary