Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect connector X16 from the PCB

Measurement:

Measure the resistance of the diverter motor and harness at the connector X16.
Motor in HW position (pin out)
ConnectionsApproximate Resistance in Ohms
3 - 58.2 Kohms
3 - 4 Open Circuit

Motor in CH position (pin in)
ConnectionsApproximate Resistance in Ohms
3 - 5Open Circuit
3 - 4 8.3 Kohms