Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
DHW Demand
Gain access to PCB (use Insulation Mat as required)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Press reset to cancel purge cycle countdown.
Allow ignition sequence to commence.
Measure DC voltage across terminals 1 (Live) and 2 (Neutral) at connector X7 on the PCB.
Expected voltage approximately 15-20 Volts DC.