Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Turn Hot Water Tap On
Attach U gauge to the burner pressure test point
Remove 1 wire from modureg and make safe
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

During the sparking stage of the ignition cycle measure the minimum burner pressure.
It should be set as per table.
Is the minimum burner pressure set correctly?
Note:
1. The burner may take some time to fully cross light this is normal and the test can still be carried out.
2. When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.