Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
For access to flue limit stat, remove fan assembly
Remove both wires from the thermostat
Remove both wires from the thermostat
Measurement:
1. Inspect flue limit stat for signs of water corrosion.
2. Measure the resistance between the terminals of the flue limit thermostat.
Expect continuity / zero resistance.
Is the resistance measured as expected?
2. Measure the resistance between the terminals of the flue limit thermostat.
Expect continuity / zero resistance.
Is the resistance measured as expected?

Isolate as per TOPs P4
and refit as necessary