XSol Diagnostic System

Interactive Test Sequence Navigator

Welcome to the XSol Diagnostic System

This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.

Start Diagnostic Sequence

or choose a specific test below:

ALPHA HE CB

GLOBALLY REPLACED

Next: &1, *

NO FAULT FOUND

Next: nff

CASE REMOVAL

Next: &3, !f2

OBSERVATION LED ILLUMINATED

SELECTOR SWITCH TO DHW AND CH POSITION
ENSURE NO DEMANDS

Next: &895, ?98, ?129

DHW FLOW RATE

Next: &119, f87

TYPE OF DIAGNOSTIC PROCEDURE

PLEASE SELECT FROM O

Next: &86, !f116

OBSERVATION PUMP RUNS

Next: &206, f424

OBSERVATION FAN RUNS

Next: &226, f209

OBSERVATION BURNER IGNITION AND ESTABLISH

REMOVE 1 WIRE FROM THE MODUREG AND MAKE SAFE

Next: &287, ?227, ?229, ?231, ?233

PRESSURE BURNER MINIMUM

ATTACH U GAUGE TO BURNER PRESSURE TEST POINT
REMOVE 1 WIRE FROM THE MODUREG AND MAKE SAFE

Next: &307, ?288, ?290

OPERATION DHW OUTPUT

BOILER DHW THERMOSTAT SET TO MAX
BOTH WIRES CONNECTED TO MODUREG

Next: &1135, ?311, ?313, ?315, ?1067

OPERATION DHW MODULATION

BOILER DHW THERMOSTA

Next: &1137, f437

OPERATION CH

CH THERMOSTAT SET TO MAX

Next: &494, ?444, ?446, ?448, ?477

OPERATION PUMP OVERRUN

Next: &nff, !f495

HEADER FOR THERMISTOR FAULT CODE

INTENTIONALLY BLANK

Next: &nff, f1194

HEADER FOR LOW PRESSURE FAULT CODE

INTENTIONALLY BLANK

Next: &nff, f508

HEADER FOR AIR FLOW FAULT CODE

INTENTIONALLY BLANK

Next: &nff, f600

HEADER FOR OVERHEAT FAULT CODE

INTENTIONALLY BLANK

Next: &nff, f651

HEADER FOR FUSE INVESTIGATION

INTENTIONALLY BLANK

Next: &nff, f721

HOW TO SET MULTIMETER TO DIODE TEST

THE IMAGES BELOW SHO

Next: &nff, !f826

OBSERVATION BOILER STANDBY

ENSURE NO DEMANDS
BOILER DHW THERMOSTAT SET TO MAX
BOILER CH THERMOSTAT SET TO MAX

Next: &115, ?896, ?916

OPERATION DHW MINIMUM FLOW RATE - DIAPHRAGM CONDITION CHECK

ENSURE APPLIANCE IS COOL
RUN HOT WATER TAP WITH A FLOW RATE OF 3 LITRES PER MINUTE

Next: &1305, !f1136

OBSERVATION DHW DEMAND END

Next: &408, !f1138

HEADER FOR RAPID TEMPERATURE RISE FAULT CODE

INTENTIONALLY BLANK

Next: &nff, f1234

PRESSURE BURNER MAXIMUM

ATTACH U GAUGE TO BU

Next: &317, f1306

BLANK FOR UNABLE TO SET MINIMUM 2

Z DIRECTION CHOICE OR CONTINUE

Next: End

MINIMUM EXCESSIVE

TUBE 4 X 8 SILICONE

Next: End

MINIMUM TOO HIGH

TUBE 4 X 8 SILICONE

Next: End

LOW 6

INLET PRESSURE

Next: End

FAULTY MODUREG

GAS VALVE - HONEYWELL VK4105M5009

Next: End

NOT GOING TO MAXIMUM PRESSURE

GAS VALVE - HONEYWELL VK4105M5009

Next: End

BLANK FOR MAXIMUM ADJUSTMENT

Z DIRECTION CHOICE OR CONTINUE

Next: End

INCORRECT MAXIMUM

TUBE 4 X 8 SILICONE

Next: End

NO MODULATION 2

SENSOR - TEMPERATURE - NTC

Next: End

SHORTED TO EARTH DAMAGED PCB

PCB AND GV & FAN/OH CABLE ASSEMBLY

Next: End

SHORTED TO EARTH BLOWING FUSE

PCB AND GV & FAN/OH CABLE ASSEMBLY

Next: End

INCORRECT MAXIMUM BAFFLING

TUBE 4 X 8 SILICONE

Next: End

LOW 6 BAFFLING

INLET PRESSURE

Next: End

FAULTY MODUREG BAFFLING

GAS VALVE - HONEYWELL VK4105M5009

Next: End

NOT GOING TO MAXIMUM PRESSURE BAFFLING

GAS VALVE - HONEYWELL VK4105M5009

Next: End

BLANK FOR MAXIMUM ADJUSTMENT BAFFLING

Z DIRECTION CHOICE OR CONTINUE

Next: End

FLUEWAYS BLOCKED AT MAX

PRIMARY HEAT EXCHANGER

Next: End

WEAK OR WORN DIAPHRAGM

DIVERTER VALVE ASSEMBLY

Next: End

INTERMITTENTLY PLAYING UP - KNOWN FAULT

SWITCH - FLOW - DHW

Next: End

TYPE DIAG PROCEDURE

DIRECTION CHOICE OR CONTINUE

Next: End

BLANK FOR FAULT CODES 2

Z DIRECTION CHOICE OR CONTINUE

Next: End

RESTRICTED BLOCKED OR SPLIT

AIR PRESSURE SWITCH TUBE

Next: End

RESTRICTED OR BLOCKED 2

PRESSURE POINT - TAKE OFF

Next: End

RESTRICTED OR BLOCKED

FLUE

Next: End

NOT MAKING AT CORRECT PRESSURE

SWITCH - AIR PRESSURE

Next: End

SPARK GAP INCORRECT

IGNITION ELECTRODES

Next: End

POOR CONDITION

KIT - IGNITION ELECTRODE LEAD

Next: End

FAULT CODE

SENSOR - TEMPERATURE - NTC

Next: End

FAULT CODE 2

SENSOR - TEMPERATURE - NTC

Next: End

THERMISTOR FAULT CODE

PCB

Next: End

THERMISTORS PLAY UP AT CERTAIN TEMPERATURES

INTERMITTENT THERMISTOR FAULT

Next: End

WATER FLOW WHEN SHOULDNT BE

DRIPPING TAP OR LEAK ON PIPEWORK

Next: End

STICKING MADE

SWITCH - FLOW - DHW

Next: End

READING COLD 2

SENSOR - TEMPERATURE - NTC

Next: End

CORRECTLY ACTIVATED

FROST PROTECTION

Next: End

RAPID TEMP RISE FAULT CODE

SYSTEM PRESSURE

Next: End

RAPID TEMP RISE FAULT CODE

PUMP 15 - 60 GRUNDFOS

Next: End

INCORRECT MAXIMUM 2

TUBE 4 X 8 SILICONE

Next: End

INCORRECT MAXIMUM

INLET PRESSURE

Next: End

INCORRECT MAXIMUM 2

GAS VALVE - HONEYWELL VK4105M5009

Next: End

INCORRECT MAXIMUM

PCB

Next: End

INCORRECT MAXIMUM

GAS VALVE - HONEYWELL VK4105M5009

Next: End

INCORRECT MAXIMUM

Z DIRECTION CHOICE OR CONTINUE

Next: End

NO MAX BP 2

SENSOR - TEMPERATURE - NTC

Next: End

NO AIR CHARGE

EXPANSION VESSEL 8 LITRES

Next: End

NOT ACTIVATING FLOW SWITCH

DIVERTER VALVE ASSEMBLY

Next: End

NOT MAKING

SWITCH - FLOW - DHW

Next: End

STOPPING DEMAND 2

SENSOR - TEMPERATURE - NTC

Next: End

BURNER IGNITION

THERMOSTAT - FLUE LIMIT

Next: End

BAFFLES OUT

HEAT EXCHANGER - CONDENSING

Next: End

BAFFLES OUT 2

HEAT EXCHANGER - CONDENSING

Next: End

NO SPARKING

HEAT EXCHANGER - CONDENSING

Next: End

DHW COOL RADS COOL

HEAT EXCHANGER - CONDENSING

Next: End

OVERHEAT FAULT CODE

HEAT EXCHANGER - CONDENSING

Next: End

DHW HOT AND COLD

HEAT EXCHANGER - CONDENSING

Next: End

FAULT CODE RAPID RISE

HEAT EXCHANGER - CONDENSING

Next: End

FILTER DHW

FILTER

Next: End

OPENING WHEN SHOULD NOT OR STUCK OPEN

BYPASS ASSEMBLY

Next: End

BURNER DOES NOT EST

TRAP - CONDENSATE

Next: End

BURNER DOES NOT EST

HEAT EXCHANGER - CONDENSING

Next: End

OUT OF CALIBRATION TRIPPING EARLY

THERMOSTAT OVERHEAT

Next: End

FAULT CODE OVERHEAT 2

THERMOSTAT - FLUE LIMIT

Next: End

FUSE FURTHER INVESTIGATION

THERMOSTAT - FLUE LIMIT

Next: End

OUT OF RANGE

SENSOR - TEMPERATURE - NTC

Next: End

READING COLD

SENSOR - TEMPERATURE - NTC

Next: End

OUT OF CALIBRATION READING HOT

SENSOR - TEMPERATURE - NTC

Next: End

PUMP NOT RUNNING OUT OF RANGE

SENSOR - TEMPERATURE - NTC

Next: End

READING HOT WHEN COLD 2

SENSOR - TEMPERATURE - NTC

Next: End

READING HOT WHEN COLD 3

SENSOR - TEMPERATURE - NTC

Next: End

READING HOT WHEN COLD 4

SENSOR - TEMPERATURE - NTC

Next: End

NO MAX BP

SENSOR - TEMPERATURE - NTC

Next: End

NO MODULATION

SENSOR - TEMPERATURE - NTC

Next: End

STOPPING DEMAND

SENSOR - TEMPERATURE - NTC

Next: End

OVERHEAT

SENSOR - TEMPERATURE - NTC

Next: End

RAPID TEMP RISE FAULT CODE

SENSOR - TEMPERATURE - NTC

Next: End

FAULT CODE AIR FLOW

HEAT EXCHANGER - CONDENSING

Next: End

BLANK FOR CASE OFF

Z DIRECTION CHOICE OR CONTINUE

Next: End

STUCK MADE

SWITCH - AIR PRESSURE

Next: End

RESTRICTED OR BLOCKED

AIR PRESSURE SWITCH TUBE

Next: End

LOW

INLET PRESSURE

Next: End

LOW 2

INLET PRESSURE

Next: End

SPARK GAP OR ALIGNTMENT INCORRECT

IGNITION ELECTRODES

Next: End

RESTRICTED OR BLOCKED

BURNER

Next: End

NOT RECTIFYING

ELECTRODE - FLAME SENSING

Next: End

NOT RECTIFYING

KIT - ELECTRODE LEAD - FLAME SENSING

Next: End

FLUEWAYS BLOCKED

PRIMARY HEAT EXCHANGER

Next: End

LOW 5

INLET PRESSURE

Next: End

READING HOT WHEN COLD 5

SENSOR - TEMPERATURE - NTC

Next: End

FAILING LIMPET - WEAK OR SLOW

PUMP 15 - 60 GRUNDFOS

Next: End

OPEN CIRCUIT TO CLOCK

CABLE - CLOCK TO TERMINAL BLOCK

Next: End

OPEN CIRCUIT

TIMER

Next: End

OPEN CIRCUIT TO CLOCK 2

CABLE - CLOCK TO TERMINAL BLOCK

Next: End

NOT TURING POT ON PCB

KNOB - CONTROL - DHW / CH

Next: End

READING HOT WHEN COLD 6

SENSOR - TEMPERATURE - NTC

Next: End

FAILING LIMPET - WEAK OR SLOW 2

PUMP 15 - 60 GRUNDFOS

Next: End

OPEN CIRCUIT TO CLOCK 3

CABLE - CLOCK TO TERMINAL BLOCK

Next: End

OPEN CIRCUIT 2

TIMER

Next: End

OPEN CIRCUIT TO CLOCK 4

CABLE - CLOCK TO TERMINAL BLOCK

Next: End

NOT SWITCHING ON

KNOB - SWITCH - SELECTOR

Next: End

NO DHW DEMAND

KNOB - SWITCH - SELECTOR

Next: End

NOT TURNING POT ON PCB 2

KNOB - CONTROL - DHW / CH

Next: End

OPEN CIRCUIT TO CLOCK 6

CABLE - CLOCK TO TERMINAL BLOCK

Next: End

OPEN CIRCUIT 3

TIMER

Next: End

OPEN CIRCUIT TO CLOCK 5

CABLE - CLOCK TO TERMINAL BLOCK

Next: End

FLAT

EXPANSION VESSEL 8 LITRES

Next: End

NOT TURNING POT ON PCB

KNOB - CONTROL - DHW / CH

Next: End

FAILING LIMPET WEAK OR SLOW 3

PUMP 15 - 60 GRUNDFOS

Next: End

OPEN TOO MUCH

Next: End

KEEPING DIVERTER IN WRONG POSITION

DRIPPING TAP OR LEAK ON PIPEWORK

Next: End

FAULTY OVERRUN

PCB

Next: End

LOW CAUSING POOR DHW

SYSTEM PRESSURE

Next: End

LOW CAUSING HOT AND COLD DHW

SYSTEM PRESSURE

Next: End

POOR HEATING

SYSTEM PRESSURE

Next: End

STUCK MADE FAULT CODE

SWITCH - AIR PRESSURE

Next: End

RESTRICTED OR BLOCKED FAULT CODE

AIR PRESSURE SWITCH TUBE

Next: End

NOT MAKING AT CORRECT PRESSURE FAULT CODE

SWITCH - AIR PRESSURE

Next: End

RESTRICTED BLOCKED OR SPLIT FAULT CODE 2

AIR PRESSURE SWITCH TUBE

Next: End

RESTRICTED OR BLOCKED FAULT CODE 2

PRESSURE POINT - TAKE OFF

Next: End

OVERHEAT FAULT CODE

SYSTEM PRESSURE

Next: End

FAILING LIMPET WEAK OR SLOW OVERHEAT

PUMP 15 - 60 GRUNDFOS

Next: End

BLOWING FUSES

GAS VALVE - HONEYWELL VK4105M5009

Next: End

CAUSING FUSE TO BLOW

FAN ASSEMBLY

Next: End

CAUSING FUSE TO BLOW

PUMP 15 - 60 GRUNDFOS

Next: End

SHUT TOO MUCH

Next: End

OPEN CIRCUIT

THERMOSTAT OVERHEAT

Next: End

GAS VALVE DAMAGED PCB

PCB AND GAS VALVE

Next: End

NO POWER TO GAS VALVE

CABLE - GAS VALVE/FAN/OVERHEAT STAT

Next: End

CAUSING FUSE TO BLOW 2

CABLE - GAS VALVE/FAN/OVERHEAT STAT

Next: End

CLOSED

ISOLATING VALVE

Next: End

OPEN CIRCUIT FAULT CODE

THERMOSTAT OVERHEAT

Next: End

STUCK MADE FAULT CODE OVERHEAT

SWITCH - AIR PRESSURE

Next: End

RESTRICTED OR BLOCKED FAULT CODE OVERHEAT

AIR PRESSURE SWITCH TUBE

Next: End

BLANK FOR MULTIMETER PAGE

Z DIRECTION CHOICE OR CONTINUE

Next: End

GAS VALVE HARNESS DAMAGED PCB

PCB AND GV & FAN/OH CABLE ASSEMBLY

Next: End

BLOWN STAND BY MODE AT POWER UP

FUSE (MAINS)

Next: End

FUSE F1

FUSE F2A 250V

Next: End

BLANK FOR PCB INVESTIGATION 2

Z DIRECTION CHOICE OR CONTINUE

Next: End

POOR DHW FLOW

VALVE - INLET 0.5 IN - COLD WATER

Next: End

INADEQUATE WATER SUPPLY

WATER SUPPLY TO PREMISES

Next: End

UNABLE TO SET MINIMUM PRESSURE NOT IGNITING

GAS VALVE - HONEYWELL VK4105M5009

Next: End

BLANK FOR MINIMUM MODUREG ADJUSTMENT

Z DIRECTION CHOICE OR CONTINUE

Next: End

UNABLE TO SET MINIMUM

GAS VALVE - HONEYWELL VK4105M5009

Next: End

BLANK FOR UNABLE TO SET MINIMUM

Z DIRECTION CHOICE OR CONTINUE

Next: End

UNABLE TO SET MINIMUM PRESSURE 2

GAS VALVE - HONEYWELL VK4105M5009

Next: End

BLANK FOR MINIMUM ADJUSTMENT NOT IGNITING

Z DIRECTION CHOICE OR CONTINUE

Next: End

SPARKING NOT IGNITING

TUBE 4 X 8 SILICONE

Next: End

LOW 3

INLET PRESSURE

Next: End

UNABLE TO SET MINIMUM PRESSURE ESTABLISH

GAS VALVE - HONEYWELL VK4105M5009

Next: End

BLANK FOR MINIMUM MODUREG ADJUSTMENT NOT ESTABLISHING

Z DIRECTION CHOICE OR CONTINUE

Next: End

IGNITING NOT ESTABLISHING

TUBE 4 X 8 SILICONE

Next: End

IGNITES BUT BAFFLES

TUBE 4 X 8 SILICONE

Next: End

LOW 4

INLET PRESSURE

Next: End

UNABLE TO SET MINIMUM 2

GAS VALVE - HONEYWELL VK4105M5009

Next: End

IGNITES BUT BAFFLES

GAS VALVE MINIMUM ADJUSTMENT

Next: End

MODUREG

NTC / APS CABLE ASSEMBLY

Next: End

POOR HOT WATER

GAS VALVE MAXIMUM ADJUSTMENT

Next: End

NOT MODULATING

PCB

Next: End

NO POWER TO GAS VALVE

PCB

Next: End

PCB CAUSING FUSE TO BLOW

PCB MAIN - FUSE

Next: End

MODUREG BAFFLING

NTC / APS CABLE ASSEMBLY

Next: End

POOR HOT WATER BAFFLING

GAS VALVE MAXIMUM ADJUSTMENT

Next: End

BLOCKED OR STUCK2

GAUGE - PRESSURE

Next: End

NO LEDS NO RESPONSE

SYSTEM PRESSURE

Next: End

NO RESPONSE WITH NO LED

PCB

Next: End

NO LEDS NO RESPONSE

CABLE- PRIMARY PRESSURE SWITCH

Next: End

FAULTY OR BLOCKED 2

SWITCH PRIMARY PRESSURE

Next: End

NO LED ILLUMINATED NO RESPONSE

LOW PRESSURE SWITCH BLOCKAGE

Next: End

NO LEDS NO RESPONSE

PIPE 18MM DIA - RS CHAMBER TO DIVERTER VALVE

Next: End

BLANK FOR FAULT CODES

Z DIRECTION CHOICE OR CONTINUE

Next: End

RUNNING BUT SLOW OR DIRTY

FAN ASSEMBLY

Next: End

SECTION TO APS OPEN CIRCUIT

NTC / APS CABLE ASSEMBLY

Next: End

NO SPARK

PCB

Next: End

FAULT CODE

NTC / APS CABLE ASSEMBLY

Next: End

FAULT CODE 2

NTC / APS CABLE ASSEMBLY

Next: End

INTERMITTENT - KNOWN ISSUE

SENSOR - TEMPERATURE - NTC

Next: End

FAULTY STUCK MADE

DIVERTER VALVE ASSEMBLY

Next: End

SECTION TO DHW THERMISTOR

NTC / APS CABLE ASSEMBLY

Next: End

FIRING WITH NO DEMAND

PCB

Next: End

RAPID TEMP RISE FAULT CODE 2

PUMP 15 - 60 GRUNDFOS

Next: End

RAPID TEMP RISE FAULT CODE

CABLE - PUMP

Next: End

RAPID TEMP RISE FAULT CODE

HEAT EXCHANGER - DHW

Next: End

BLANK FOR RAPID TEMPERATUR INCREASE

Z DIRECTION CHOICE OR CONTINUE

Next: End

INCORRECT MAXIMUM

NTC / APS CABLE ASSEMBLY

Next: End

INCORRECT MAXIMUM

GAS VALVE MAXIMUM ADJUSTMENT

Next: End

FAULT CODE

SYSTEM PRESSURE

Next: End

WORN NIPPLE

SWITCH - FLOW - DHW

Next: End

SECTION TO DHW MICROSWITCH

NTC / APS CABLE ASSEMBLY

Next: End

BLOCKED OR STUCK 3

GAUGE - PRESSURE

Next: End

PUMP DOES NOT RUN

SYSTEM PRESSURE

Next: End

PUMP DOES NOT RUN

PCB

Next: End

PUMP DOES NOT RUN

CABLE- PRIMARY PRESSURE SWITCH

Next: End

FAULTY OR BLOCKED 3

SWITCH PRIMARY PRESSURE

Next: End

PUMP DOES NOT RUN

LOW PRESSURE SWITCH BLOCKAGE

Next: End

PUMP DOES NOT RUN

PIPE 18MM DIA - RS CHAMBER TO DIVERTER VALVE

Next: End

NO POWER TO FAN

PCB

Next: End

FAN NOT RUNNING

NTC / APS CABLE ASSEMBLY

Next: End

OPEN CIRCUIT WIRES TO OVERHEAT STAT

CABLE - GAS VALVE/FAN/OVERHEAT STAT

Next: End

DHW COOL RADS COOL

PRIMARY HEAT EXCHANGER - WATERWAYS

Next: End

FAULT CODE OVERHEAT

PRIMARY HEAT EXCHANGER - WATERWAYS

Next: End

DHW HOT AND COLD

PRIMARY HEAT EXCHANGER - WATERWAYS

Next: End

RAPID TEMP RISE FAULT CODE

PRIMARY HEAT EXCHANGER - WATERWAYS

Next: End

HEAT EXCHANGER - DHW

HEAT EXCHANGER - DHW

Next: End

BURNER DOES NOT EST

CONDENSATE LEVEL SENSOR

Next: End

FAULT CODE

OVERHEAT INFORMATION PAGE

Next: End

FAULT CODE OVERHEAT

THERMOSTAT - FLUE LIMIT

Next: End

OPEN CIRCUIT WIRES TO OVERHEAT FAULT CODE

CABLE - GAS VALVE/FAN/OVERHEAT STAT

Next: End

SEIZED OR BURNT OUT

FAN ASSEMBLY

Next: End

NO POWER TO FAN

CABLE - GAS VALVE/FAN/OVERHEAT STAT

Next: End

SECTION TO APS SHORTED

NTC / APS CABLE ASSEMBLY

Next: End

RESTRICTED OR BLOCKED

PRESSURE POINT - TAKE OFF

Next: End

RESTRICTED OR BLOCKED

MANIFOLD - GAS

Next: End

NOT RECTIFYING

PCB

Next: End

PASSING TO RADIATORS

DIVERTER VALVE ASSEMBLY

Next: End

RESTRICTED OR BLOCKED

HEAT EXCHANGER - DHW

Next: End

RESTRICTED OR BLOCKED 2

HEAT EXCHANGER - DHW

Next: End

NOT RUNNING

PUMP 15 - 60 GRUNDFOS

Next: End

NO POWER TO PUMP

CABLE - PUMP

Next: End

BLOCKED

PIPE 8MM DIA - EXPANSION VESSEL

Next: End

STUCK IN DHW POSITION

DIVERTER VALVE ASSEMBLY

Next: End

POOR CIRCULATION

Next: End

BLOCKED OR STUCK

GAUGE - PRESSURE

Next: End

LOW PRESSURE FAULT CODE

PCB

Next: End

TO PRESSURE SWITCH

CABLE- PRIMARY PRESSURE SWITCH

Next: End

BLOCKED OR STUCK BUT SHOWING SOME PRESSURE

GAUGE - PRESSURE

Next: End

SEIZED OR BURNT OUT FAULT CODE

FAN ASSEMBLY

Next: End

NO POWER TO FAN FAULT CODE

CABLE - GAS VALVE/FAN/OVERHEAT STAT

Next: End

SECTION TO APS SHORTED FAULT CODE

NTC / APS CABLE ASSEMBLY

Next: End

RESTRICTED OR BLOCKED FAULT CODE

PRESSURE POINT - TAKE OFF

Next: End

SECTION TO APS OPEN CIRCUIT FAULT CODE

NTC / APS CABLE ASSEMBLY

Next: End

RUNNING BUT SLOW OR DIRTY FAULT CODE

FAN ASSEMBLY

Next: End

AIR FLOW FAULT CODE

PCB

Next: End

NOT RUNNING OVERHEAT

PUMP 15 - 60 GRUNDFOS

Next: End

NO POWER TO PUMP FAULT CODE

CABLE - PUMP

Next: End

RESTRICTED OR BLOCKED OVERHEAT

HEAT EXCHANGER - DHW

Next: End

CAUSING FUSE TO BLOW

CABLE - GAS VALVE/FAN/OVERHEAT STAT

Next: End

CAUSING FUSE TO BLOW

CABLE - PUMP

Next: End

NO IGNITION PRESSURE

GAS VALVE - HONEYWELL VK4105M5009

Next: End

SECTION TO APS SHORTED FAULT CODE OVERHEAT

NTC / APS CABLE ASSEMBLY

Next: End

RESTRICTED OR BLOCKED FAULT CODE OVERHEAT

PRESSURE POINT - TAKE OFF

Next: End

FAULTY OR BLOCKED

SWITCH PRIMARY PRESSURE

Next: End

FAULT CODE

LOW PRESSURE SWITCH BLOCKAGE

Next: End

FAULT CODE

PIPE 18MM DIA - RS CHAMBER TO DIVERTER VALVE

Next: End

FURTHER INVESTIGATION FUSE F1

Z DIRECTION CHOICE OR CONTINUE

Next: End

INCOMING MAINS WIRING

CABLE - CLOCK TO TERMINAL BLOCK

Next: End

BLANK FOR PCB INVESTIGATION

Z DIRECTION CHOICE OR CONTINUE

Next: End

FAN RUNNING CONTINUOUSLY

PCB

Next: End

RESTRICTED OR BLOCKED 2

MANIFOLD - GAS

Next: End

FURTHER INVESTIGATION MAINS FUSE

Z DIRECTION CHOICE OR CONTINUE

Next: End

NOT IGNITING

GAS VALVE MINIMUM ADJUSTMENT

Next: End

MINIMUM SET TOO HIGH

GAS VALVE MINIMUM ADJUSTMENT

Next: End

MINIMUM TOO LOW

GAS VALVE MINIMUM ADJUSTMENT

Next: End

IGNITING BUT NOT ESTABLISHING

GAS VALVE MINIMUM ADJUSTMENT

Next: End

BURNER BAFFLES DURING DHW OPERATION

CHARACTERISTIC TEST FROM OPERATION DHW OUTPUT

Next: p1069

SYSTEM PRESSURE OK BUT GAUGE DOES NOT CHANGE WHEN PRESSURE ADDED

CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE NO RESPONSE

Next: !p1095

SYSTEM PRESSURE LOW AND GAUGE DOES NOT CHANGE WHEN PRESSURE ADDED

CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE NO RESPONSE

Next: !p1097

SYSTEM PRESSURE LOW AND GAUGE DOES CHANGE WHEN PRESSURE ADDED

CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE NO RESPONSE

Next: !p1099

LOW PRESSURE SWITCH BLOCKED OR RESTRICTED

CHARACTERISTIC TEST FROM INSPECTION LOW PRESSURE SWITCH AND CONNECTION

Next: !p1106

LOW PRESSURE SWITCH CONNECTION BLOCKED OR RESTRICTED

CHARACTERISTIC TEST FROM INSPECTION LOW PRESSURE SWITCH AND CONNECTION

Next: !p1108

NO LEDS ILLUMINATED

CHARACTERISTIC TEST FROM OBSERVATION LED ILLUMINATED

Next: p409

SYSTEM PRESSURE OK BUT GAUGE DOES NOT CHANGE WHEN PRESSURE ADDED

CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE NO RESPONSE

Next: !p1371

SYSTEM PRESSURE LOW AND GAUGE DOES NOT CHANGE WHEN PRESSURE ADDED

CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE NO RESPONSE

Next: !p1373

SYSTEM PRESSURE LOW AND GAUGE DOES CHANGE WHEN PRESSURE ADDED

CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE NO RESPONSE

Next: !p1375

LOW PRESSURE SWITCH BLOCKED OR RESTRICTED

CHARACTERISTIC TEST FROM INSPECTION LOW PRESSURE SWITCH AND CONNECTION

Next: !p1382

LOW PRESSURE SWITCH CONNECTION BLOCKED OR RESTRICTED

CHARACTERISTIC TEST FROM INSPECTION LOW PRESSURE SWITCH AND CONNECTION

Next: !p1384

SPARKING OCCURS BUT BURNER DOES NOT IGNITE

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION AND ESTABLISH

Next: p228

SPARKING DOES NOT OCCUR

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION AND ESTABLISH

Next: p1172

BURNER IGNITES SMOOTHLY BUT DOES NOT ESTABLISH (SPARKING CONTINUES)

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION AND ESTABLISH

Next: p232

BURNER IGNITES BUT BAFFLES OUT

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION AND ESTABLISH

Next: p294

NO PRESSURE MEASURED

CHARACTERISTIC TEST FROM PRESSURE BURNER IGNITION

Next: p257

PRESSURE PRESENT BUT INCORRECT

CHARACTERISTIC TEST FROM PRESSURE BURNER IGNITION

Next: p974

PRESSURE EXCESSIVE

CHARACTERISTIC TEST FROM PRESSURE BURNER MINIMUM

Next: p1002

PRESSURE LOW

CHARACTERISTIC TEST FROM PRESSURE BURNER MINIMUM

Next: p308

TEMP RISE UNSATISFACTORY RADS BEGIN TO HEAT WITH NO CH DEMAND

CHARACTERISTIC TEST FROM OPERATION DHW OUTPUT

Next: !p312

TEMP RISE UNSATISFACTORY RADS DO NOT BEGIN TO HEAT WITH NO CH DEMAND

CHARACTERISTIC TEST FROM OPERATION DHW OUTPUT

Next: p526

DHW RUNS HOT AND COLD

CHARACTERISTIC TEST FROM OPERATION DHW OUTPUT

Next: p557

TEMPERATURE DIFFERENTIAL STILL EXCESSIVE

CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE FOR PUMP NOT RUNNING

Next: p1439

BOILER DOES NOT RESPOND TO CH DEMAND

CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE FOR PUMP NOT RUNNING

Next: p359

TEMPERATURE DIFFERENTIAL STILL EXCESSIVE

CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE FOR PUMP NOT RUNNING

Next: p1446

BOILER DOES NOT RESPOND TO CH DEMAND

CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE FOR PUMP NOT RUNNING

Next: p387

BOILER DOES NOT REACT TO CH DEMAND

CHARACTERISTIC TEST FROM OPERATION CH

Next: p450

EXCESSIVE SYSTEM PRESSURE RISE AS TEMPERATURE INCREASES

CHARACTERISTIC TEST FROM OPERATION CH

Next: p447

BOILER AND RADIATOR TEMPERATURE REMAINS LOW

CHARACTERISTIC TEST FROM OPERATION CH

Next: p449

SYSTEM PRESSURE OK BUT GAUGE DOES NOT CHANGE WHEN PRESSURE ADDED

CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE NO RESPONSE

Next: !p516

SYSTEM PRESSURE LOW AND GAUGE DOES NOT CHANGE WHEN PRESSURE ADDED

CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE NO RESPONSE

Next: !p556

SYSTEM PRESSURE LOW AND GAUGE DOES CHANGE WHEN PRESSURE ADDED

CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE NO RESPONSE

Next: p1351

OVERHEAT FAULT CODE OCCURS BELOW 82 DEGREES

CHARACTERISTIC TEST FROM OBSERVATION RUN APPLIANCE TO MAX TEMP

Next: p1476

BOILER TEMPERATURE EXCEEDS 82 DEGREES AND BURNER REMAINS ALIGHT

CHARACTERISTIC TEST FROM OBSERVATION RUN APPLIANCE TO MAX TEMP

Next: !p718

BURNER DOES NOT RE IGNITE AND OVERHEAT FAULT CODE RETURNS

CHARACTERISTIC TEST FROM OBSERVATION BOILER RESET TEMPERATURE RELATED FAULT

Next: p811

BOILER DOES NOT COMMENCE IGNTION SEQUENCE OVERHEAT FAULT CODE REMAINS

CHARACTERISTIC TEST FROM OBSERVATION BOILER RESET TEMPERATURE RELATED FAULT

Next: p816

LOW PRESSURE SWITCH BLOCKED OR RESTRICTED

CHARACTERISTIC TEST FROM INSPECTION LOW PRESSURE SWITCH AND CONNECTION

Next: !p834

LOW PRESSURE SWITCH CONNECTION BLOCKED OR RESTRICTED

CHARACTERISTIC TEST FROM INSPECTION LOW PRESSURE SWITCH AND CONNECTION

Next: !p836

BOILER TRIES TO FIRE WITH NO DEMAND

CHARACTERISTIC TEST FROM OBSERVATION BOILER STANDBY

Next: p1212

FAN RUNS CONTINUOUSLY BUT BOILER DOES NOT ATTEMPT TO FIRE

CHARACTERISTIC TEST FROM OBSERVATION BOILER STANDBY

Next: p917

FAULT CODE SHOWN

CHARACTERISTIC TEST FROM OBSERVATION LED ILLUMINATED

Next: p99

INSPECTION VENT TUBE GAS VALVE

Next: p1034, !f1047

RESISTANCE MODUREG

REMOVE BOTH WIRES FROM THE MODUREG

Next: !p1039, !f1040

INSPECTION VENT TUBE GAS VALVE

Next: p1072, !f1073

RESISTANCE MODUREG

REMOVE BOTH WIRES FROM THE MODUREG

Next: !p1078, !f1079

RESISTANCE LOW PRESSURE SWITCH

REMOVE THE TWO WIRES FROM THE LOW WATER PRESSURE SWITCH MAKING A NOTE OF THEIR LOCATIONS

Next: !p1102, f1103

INSPECTION LOW PRESSURE SWITCH AND CONNECTION

APPLIANCE DRAINED AND DISCHARGED
REMOVE THE LOW WATER PRESSURE SWITCH

Next: !p1104, ?1105, ?1107

RESISTANCE APS AND HARNESS USING TEST KIT

REMOVE CONNECTOR M5 FROM THE PCB
REMOVE TUBE FROM FRONT CONNECTOR OF APS

Next: p1189, f1186

RESISTANCE APS USING TEST KIT

DISCONNECT LEADS FRO

Next: !p1187, !f1188

RESISTANCE THERMISTOR PRIMARY AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: p1195, f1196

RESISTANCE THERMISTOR PRIMARY

REMOVE THE CONNECTOR

Next: !p1197, !f1198

RESISTANCE THERMISTOR DHW

REMOVE CONNECTOR FROM DHW THERMISTOR

Next: !p1201, !f1202

OBSERVATION ISOLATE WATER SUPPLY TO BOILER

ISOLATE THE DHW SUPPLY TO THE APPLIANCE

Next: p1217, !f1218

RESISTANCE THERMISTOR DHW

REMOVE CONNECTOR FROM DHW THERMISTOR

Next: !p1228, !f1229

VOLTAGE PUMP AT PUMP

REMOVE THE COVER FROM THE PUMP ASSEMBLY

Next: !p1239, f1240

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: !p1241, !f1242

TEMPERATURE DIFFERENTIAL CH

ATTACH TEMPERATURE C

Next: !p1294, f1449

INSPECTION VENT TUBE GAS VALVE

Next: p1321, !f1308

RESISTANCE MODUREG

REMOVE BOTH WIRES FROM THE MODUREG

Next: !p1313, !f1314

RESISTANCE DHW MICROSWITCH AND HARNESS PUMP NOT RUNNING

REMOVE CONNECTOR M5 FROM THE PCB

Next: p1360, f1361

RESISTANCE DHW MICROSWITCH

DISCONNECT THE INLIN

Next: !p1362, !f1363

RESISTANCE LOW PRESSURE SWITCH

REMOVE THE TWO WIRES FROM THE LOW WATER PRESSURE SWITCH MAKING A NOTE OF THEIR LOCATIONS

Next: !p1378, f1379

INSPECTION LOW PRESSURE SWITCH AND CONNECTION

APPLIANCE DRAINED AND DISCHARGED
REMOVE THE LOW WATER PRESSURE SWITCH

Next: !p1380, ?1381, ?1383

RESISTANCE THERMISTOR DHW

REMOVE CONNECTOR FROM DHW THERMISTOR

Next: !p1401, !f1402

INSPECTION CONDENSING HEAT EXCHANGER WATERWAYS

DRAIN PRIMARY CIRCUIT OF WATER
REMOVE FLOW AND RETURN PIPES TO CONDENSING HEAT EXCHANGER

Next: !p1444, !f1445

INSPECTION CONDENSING HEAT EXCHANGER WATERWAYS

DRAIN PRIMARY CIRCUIT OF WATER
REMOVE FLOW AND RETURN PIPES TO CONDENSING HEAT EXCHANGER

Next: !p1450, !f1451

INSPECTION INTEGRAL BYPASS

APPLIANCE DRAINED AN

Next: !p1460, !f1461

INSPECTION CONDENSATE PIPE

Next: p1469, !f1470

VOLTAGE FAN AT FAN

Next: !p210, f211

VOLTAGE FAN AT PCB

{GAINPCBACS}

Next: !p212, f213

RESISTANCE AIR PRESSURE SWITCH AND HARNESS AT REST

REMOVE CONNECTOR M5 FROM THE PCB

Next: p1386, f215

RESISTANCE AIR PRESSURE SWITCH AT REST

REMOVE THE WIRES FROM THE AIR PRESSURE SWITCH NOTING THEIR LOCATIONS

Next: !p218, f219

RESISTANCE APS TUBE DISCONNECTED

DISCONNECT AIR PRESSURE PIPE FROM APS

Next: p220, !f221

TEMPERATURE DIFFERENTIAL CH

ATTACH TEMPERATURE C

Next: !p355, ?356, ?358

RESISTANCE EXTERNAL CONTROLS HARNESS

REMOVE CONNECTOR M1 FROM THE PCB

Next: !p364, !f365

TEMPERATURE DIFFERENTIAL CH

ATTACH TEMPERATURE C

Next: !p383, ?384, ?386

RESISTANCE EXTERNAL CONTROLS HARNESS

REMOVE CONNECTOR M1 FROM THE PCB

Next: !p392, !f393

INSPECTION SELECTOR SWITCH

GAIN ACCESS TO PCB

Next: p425, !f436

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: !p428, f429

OBSERVATION DISCONNECT DHW MICROSWITCH

REMOVE THE DHW MICRO

Next: p1354, f1359

INSPECTION DHW TEMPERATURE CONTROL KNOB

GAIN ACCESS TO PCB

Next: p1056, !f443

RESISTANCE EXTERNAL CONTROLS HARNESS

REMOVE CONNECTOR M1 FROM THE PCB

Next: !p455, !f456

TEMPERATURE HEATING FLOW INCREASE - INTERNAL DHW ISOLATED

ISOLATE COLD WATER S

Next: !p488, !f489

INSPECTION SYSTEM PRESSURE FOR FAULT CODE

Next: p513, ?515, ?517, ?520

RESISTANCE LOW PRESSURE SWITCH

REMOVE THE TWO WIRES FROM THE LOW WATER PRESSURE SWITCH MAKING A NOTE OF THEIR LOCATIONS

Next: !p524, f831

OBSERVATION FAN RUNS

Next: p621, f601

VOLTAGE FAN AT FAN

Next: !p602, f603

VOLTAGE FAN AT PCB

{GAINPCBACS}

Next: !p604, f605

RESISTANCE AIR PRESSURE SWITCH AND HARNESS AT REST

REMOVE CONNECTOR M5 FROM THE PCB

Next: !p657, f607

RESISTANCE AIR PRESSURE SWITCH AT REST

REMOVE THE WIRES FROM THE AIR PRESSURE SWITCH NOTING THEIR LOCATIONS

Next: !p608, f609

RESISTANCE APS TUBE DISCONNECTED

DISCONNECT AIR PRESSURE PIPE FROM APS

Next: p610, !f611

RESISTANCE APS USING TEST KIT

DISCONNECT LEADS FRO

Next: !p624, !f625

OBSERVATION BOILER RESET OVERHEAT FAULT

ENSURE APPLIANCE IS COOL (BELOW 40°C)

Next: p696, ?807, ?809

VOLTAGE PUMP AT PUMP

REMOVE THE COVER FROM THE PUMP ASSEMBLY

Next: !p701, f702

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: !p703, !f704

TEMPERATURE DIFFERENTIAL CH

ATTACH TEMPERATURE C

Next: !p711, f1443

RESISTANCE PUMP AND HARNESS AND TO EARTH

REMOVE CONNECTOR M12 FROM THE PCB

Next: p722, f725

RESISTANCE PUMP AND TO EARTH

REMOVE THE COVER FROM THE PUMP ASSEMBLY
REMOVE THE WIRES FROM THE PUMP ASSEMBLY

Next: !p732, !f733

RESISTANCE FAN AND TO EARTH

REMOVE THE WIRES FROM THE FAN ASSEMBLY

Next: !p730, !f731

RESISTANCE OVERHEAT STATS AND HARNESS

REMOVE CONNECTOR M7 FROM THE PCB

Next: p777, f778

RESISTANCE OVERHEAT STAT

REMOVE BOTH WIRES FROM THE OVERHEAT THERMOSTAT

Next: p1425, !f780

RESISTANCE OVERHEAT STAT

REMOVE BOTH WIRES FROM THE OVERHEAT THERMOSTAT

Next: p1480, !f815

RESISTANCE AIR PRESSURE SWITCH AT REST

REMOVE THE WIRES FROM THE AIR PRESSURE SWITCH NOTING THEIR LOCATIONS

Next: !p819, f820

RESISTANCE APS TUBE DISCONNECTED

DISCONNECT AIR PRESSURE PIPE FROM APS

Next: p821, !f822

INSPECTION LOW PRESSURE SWITCH AND CONNECTION

APPLIANCE DRAINED AND DISCHARGED
REMOVE THE LOW WATER PRESSURE SWITCH

Next: !p832, ?833, ?835

VOLTAGE MAINS INTO APPLIANCE

Next: p852, f853

RESISTANCE FUSE MAIN

GAIN ACCESS TO THE INCOMING MAINS FUSE

Next: !p854, f855

FUSE FURTHER INVESTIGATION MAIN

Next: !p953, !f857

FUSE FURTHER INVESTIGATION F2A

Next: !p860, !f861

RESISTANCE THERMISTOR PRIMARY AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: p1092, !f1502

INSPECTION VENT TUBE GAS VALVE

Next: p984, !f991

INSPECTION VENT TUBE GAS VALVE

Next: p995, !f994

INSPECTION VENT TUBE GAS VALVE

Next: p746, !f1008

INSPECTION VENT TUBE GAS VALVE

Next: p742, !f1015

TEMPERATURE DIFFERENTIAL CH

ATTACH TEMPERATURE C

Next: p709, !f1027

PRESSURE GAS INLET BURNER ESTABLISHED

ATTACH U GAUGE TO INLET PRESSURE TEST POINT

Next: p1035, !f1036

RESISTANCE MODUREG AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: p1037, f1038

VOLTAGE MODUREG

HOT WATER TAP ON AND FULLY OPEN

Next: p1041, !f1042

PRESSURE GAS MAXIMUM ADJUSTMENT

ATTACH U GAUGE TO BU

Next: p1043, !f1044

CORRECTION GAS VALVE MAXIMUM

Next: !p1045, !f1046

RESISTANCE THERMISTOR PRIMARY AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: p1057, !f1510

RESISTANCE THERMISTOR DHW

REMOVE CONNECTOR FROM DHW THERMISTOR

Next: !p1059, !f1060

RESISTANCE HARNESS GAS VALVE TO EARTH

ENSURE GAS VALVE CONNECTOR IS RE ATTACHED TO GAS VALVE
REMOVE CONNECTOR M7 FROM THE PCB

Next: !p1062, !f1063

RESISTANCE HARNESS GAS VALVE TO EARTH

ENSURE GAS VALVE CONNECTOR IS RE ATTACHED TO GAS VALVE
REMOVE CONNECTOR M7 FROM THE PCB

Next: !p1065, !f1066

PRESSURE BURNER MAXIMUM

ATTACH U GAUGE TO BU

Next: p1087, f1071

PRESSURE GAS INLET BURNER ESTABLISHED

ATTACH U GAUGE TO INLET PRESSURE TEST POINT

Next: p1074, !f1075

RESISTANCE MODUREG AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: p1076, f1077

VOLTAGE MODUREG

HOT WATER TAP ON AND FULLY OPEN

Next: p1080, !f1081

PRESSURE GAS MAXIMUM ADJUSTMENT

ATTACH U GAUGE TO BU

Next: p1082, !f1083

CORRECTION GAS VALVE MAXIMUM

Next: !p1084, !f1085

INSPECTION BURNER ASSEMBLY

GAIN ACCESS TO BURNER ASSEMBLY

Next: p1088, !f1089

INSPECTION SYSTEM PRESSURE NO RESPONSE

Next: p1093, ?1094, ?1096, ?1098

RESISTANCE LOW PRESSURE SWITCH AND HARNESS

REMOVE CONNECTOR M4 FROM THE PCB

Next: !p1100, f1101

INSPECTION FILTER

ISOLATE INCOMING WATER SUPPLY TO APPLIANCE

Next: !p1457, !f1458

OBSERVATION SPARKING OCCUR WITH APS MADE

REMOVE TUBE FROM FRONT CONNECTOR OF APS

Next: p1178, f1185

INSPECTION AIR PRESSURE TUBE

Next: p1179, !f1180

INSPECTION AIR PRESSURE PIPE

REMOVE THE INNER COM

Next: p1434, !f1182

INSPECTION FLUE

Next: !p1183, !f1184

INSPECTION SPARK ELECTRODES

REMOVE THE SPARK ELECTRODE LEADS FROM THE SPARK ELECTRODES

Next: p1190, !f1191

RESISTANCE ELECTRODE LEADS

DISCONNECT THE ELECTRODE LEADS FROM THE SPARK ELECTRODES AND THE SPARK GENERATOR ON THE PCB

Next: !p1192, !f1193

RESISTANCE THERMISTOR DHW AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: p1204, f1200

OBSERVATION BOILER RESET THERMISTOR FAULT CODE

NO DEMANDS
SELECT

Next: p1205, !f1208

OBSERVATION DISCONNECT EXTERNAL CONTROLS OR LINK

REMOVE THE WIRING TO

Next: p1213, !f1214

RESISTANCE DHW MICROSWITCH AND HARNESS

REMOVE CONNECTOR M5 FROM THE PCB

Next: p1222, f1216

RESISTANCE DHW MICROSWITCH

DISCONNECT THE INLIN

Next: !p1219, !f1220

RESISTANCE THERMISTOR PRIMARY AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: p1223, !f1503

RESISTANCE THERMISTOR DHW AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: p1230, f1227

TEMPERATURE APPLIANCE

Next: !p1232, !f1231

OBSERVATION PUMP RUNS

Next: p1237, f1238

PUMP LIMPET

Next: p1289, !f1244

RESISTANCE THERMISTOR PRIMARY AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: p1235, !f1513

EXTERNAL BYPASS

Next: p1290, !f1291

TEMPERATURE DIFFERENTIAL DHW

FLOW RATE AT HOT TAP

Next: p1292, f1293

TEMPERATURE DIFFERENTIAL CH - RAPID TEMP RISE

ATTACH TEMPERATURE C

Next: !p1304, !f1297

PRESSURE GAS INLET BURNER ESTABLISHED

ATTACH U GAUGE TO INLET PRESSURE TEST POINT

Next: p1309, !f1310

RESISTANCE MODUREG AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: p1311, f1312

VOLTAGE MODUREG

HOT WATER TAP ON AND FULLY OPEN

Next: p1315, !f1316

PRESSURE GAS MAXIMUM ADJUSTMENT

ATTACH U GAUGE TO BU

Next: p1317, !f1318

RESISTANCE THERMISTOR PRIMARY AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: p1335, !f1509

RESISTANCE THERMISTOR DHW

REMOVE CONNECTOR FROM DHW THERMISTOR

Next: p1307, !f1350

PRESSURE EXPANSION VESSEL

APPLIANCE PRIMARY CIRCUIT DRAINED AND DISCHARGED

Next: !p1352, !f1353

INSPECTION DIVERTER MOVEMENT

REMOVE THE MICROSWITCH FROM THE TOP OF THE DIVERTER VALVE AND PLACE IN A SAFE POSITION.

Next: !p1358, !f1355

RESISTANCE THERMISTOR PRIMARY AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: p1364, !f1505

INSPECTION SYSTEM PRESSURE FOR PUMP NOT RUNNING

Next: p1368, ?1370, ?1372, ?1374

RESISTANCE LOW PRESSURE SWITCH AND HARNESS

REMOVE CONNECTOR M4 FROM THE PCB

Next: !p1376, f1377

RESISTANCE THERMISTOR PRIMARY AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: p1398, !f1506

RESISTANCE THERMISTOR DHW AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: !p1399, f1400

RESISTANCE FLUE LIMIT STAT

FOR ACCESS TO FLUE LIMIT STAT, REMOVE FAN ASSEMBLY
REMOVE BOTH WIRES FROM THE THERMOSTAT

Next: !p1426, !f1427

INSPECTION HEAT EXCHANGER CONDENSING FLUE WAYS

REMOVE FAN ASSEMBLY FROM BOILER

Next: !p1429, !f1430

INSPECTION HEAT EXCHANGER CONDENSING FLUE WAYS

REMOVE FAN ASSEMBLY FROM BOILER

Next: !p1432, !f1433

INSPECTION HEAT EXCHANGER CONDENSING FLUE WAYS

REMOVE FAN ASSEMBLY FROM BOILER

Next: p1181, !f1438

INSPECTION CONDENSING HEAT EXCHANGER WATERWAYS

DRAIN PRIMARY CIRCUIT OF WATER
REMOVE FLOW AND RETURN PIPES TO CONDENSING HEAT EXCHANGER

Next: !p1440, !f1442

INSPECTION CONDENSING HEAT EXCHANGER WATERWAYS

DRAIN PRIMARY CIRCUIT OF WATER
REMOVE FLOW AND RETURN PIPES TO CONDENSING HEAT EXCHANGER

Next: !p1447, !f1448

OBSERVATION CONDENSATE LEVEL SENSOR DISCONNECTED

REMOVE WIRES FROM CONDENSATE LEVEL SENSOR

Next: p282, f1468

INSPECTION HEAT EXCHANGER CONDENSING

REMOVE FAN ASSEMBLY

Next: !p1471, !f1472

RESISTANCE OVERHEAT STAT

REMOVE BOTH WIRES FROM THE OVERHEAT THERMOSTAT

Next: !p1478, !f1479

RESISTANCE FLUE LIMIT STAT

FOR ACCESS TO FLUE LIMIT STAT, REMOVE FAN ASSEMBLY
REMOVE BOTH WIRES FROM THE THERMOSTAT

Next: !p1481, !f1482

INSPECTION HEAT EXCHANGER CONDENSING FLUE WAYS

REMOVE FAN ASSEMBLY FROM BOILER

Next: p646, !f1518

INSPECTION AIR PRESSURE TUBE

Next: !p222, !f223

PRESSURE BURNER IGNITION

ATTACH U GAUGE TO THE BURNER PRESSURE TEST POINT
REMOVE 1 WIRE FROM MODUREG AND MAKE SAFE

Next: p255, ?256, ?258

PRESSURE BURNER IGNITION

ATTACH U GAUGE TO THE BURNER PRESSURE TEST POINT
REMOVE 1 WIRE FROM MODUREG AND MAKE SAFE

Next: p1462, f983

INSPECTION BURNER ASSEMBLY

GAIN ACCESS TO BURNER ASSEMBLY

Next: p293, !f302

PRESSURE GAS INLET

ATTACH U GAUGE TO INLET PRESSURE TEST POINT

Next: p774, !f265

PRESSURE GAS INLET

ATTACH U GAUGE TO INLET PRESSURE TEST POINT

Next: p735, !f263

INSPECTION BURNER ASSEMBLY

GAIN ACCESS TO BURNER ASSEMBLY

Next: !p275, !f276

INSPECTION ELECTRODE DETECTION AND LEAD

DISCONNECT THE INLINE CONNECTOR ON THE DETECTION LEAD

Next: p283, !f284

RESISTANCE DETECTION LEAD SECTION 2

REMOVE CONNECTOR M10 FROM PCB

Next: !p285, !f286

PRESSURE BURNER IGNITION

ATTACH U GAUGE TO THE BURNER PRESSURE TEST POINT
REMOVE 1 WIRE FROM MODUREG AND MAKE SAFE

Next: p234, f992

PRESSURE GAS INLET BURNER ESTABLISHED

ATTACH U GAUGE TO INLET PRESSURE TEST POINT

Next: p1009, !f310

INSPECTION DHW TEMPERATURE CONTROL KNOB

GAIN ACCESS TO PCB

Next: p333, !f373

RESISTANCE THERMISTOR PRIMARY AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: p334, !f1507

RESISTANCE THERMISTOR DHW

REMOVE CONNECTOR FROM DHW THERMISTOR

Next: p335, !f344

PUMP LIMPET

Next: p336, !f345

TEMPERATURE DIFFERENTIAL DHW

FLOW RATE AT HOT TAP

Next: p934, f346

OBSERVATION LINK EXTERNAL CONTROLS

REMOVE THE EXTERNAL

Next: p360, !f361

OBSERVATION TIMER FITTED

Next: p362, f363

RESISTANCE INTEGRAL TIMER

REMOVE THE WIRES FROM TERMINALS 3 AND 4 ON THE INTEGRAL TIMER

Next: p366, !f367

RESISTANCE EXTERNAL CONTROLS HARNESS

REMOVE CONNECTOR M1 FROM THE PCB

Next: !p371, !f372

RESISTANCE THERMISTOR PRIMARY AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: p375, !f1508

RESISTANCE THERMISTOR DHW

REMOVE CONNECTOR FROM DHW THERMISTOR

Next: p377, !f378

PUMP LIMPET

Next: p379, !f380

TEMPERATURE DIFFERENTIAL DHW

FLOW RATE AT HOT TAP

Next: !p401, f382

OBSERVATION LINK EXTERNAL CONTROLS

REMOVE THE EXTERNAL

Next: p388, !f389

OBSERVATION TIMER FITTED

Next: p390, f391

RESISTANCE INTEGRAL TIMER

REMOVE THE WIRES FROM TERMINALS 3 AND 4 ON THE INTEGRAL TIMER

Next: p394, !f395

RESISTANCE EXTERNAL CONTROLS HARNESS

REMOVE CONNECTOR M1 FROM THE PCB

Next: !p396, !f397

INSPECTION SELECTOR SWITCH

GAIN ACCESS TO PCB

Next: p837, !f423

VOLTAGE PUMP AT PUMP

REMOVE THE COVER FROM THE PUMP ASSEMBLY

Next: !p426, f427

PRESSURE EXPANSION VESSEL

APPLIANCE PRIMARY CIRCUIT DRAINED AND DISCHARGED

Next: !p461, !f462

INSPECTION CH TEMPERATURE CONTROL KNOB

GAIN ACCESS TO PCB

Next: p463, !f464

OBSERVATION LINK EXTERNAL CONTROLS

REMOVE THE EXTERNAL

Next: p451, !f452

OBSERVATION TIMER FITTED

Next: p453, f454

RESISTANCE INTEGRAL TIMER

REMOVE THE WIRES FROM TERMINALS 3 AND 4 ON THE INTEGRAL TIMER

Next: p457, !f458

RESISTANCE EXTERNAL CONTROLS HARNESS

REMOVE CONNECTOR M1 FROM THE PCB

Next: !p459, !f460

RESISTANCE THERMISTOR PRIMARY AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: !p465, !f1511

PUMP LIMPET

Next: p483, !f482

TEMPERATURE HEATING FLOW INCREASE - INTERNAL

ATTACH ONE TEMPERATU

Next: p480, f481

TEMPERATURE DIFFERENTIAL FLOW PIPE EXTERNAL AND RETURN

ATTACH 1 TEMPERATURE

Next: !p490, f1459

EXTERNAL BYPASS

Next: p479, !f487

RESISTANCE LOW PRESSURE SWITCH AND HARNESS

REMOVE CONNECTOR M4 FROM THE PCB

Next: !p522, f523

INSPECTION AIR PRESSURE TUBE

Next: !p612, !f613

RESISTANCE APS AND HARNESS USING TEST KIT

REMOVE CONNECTOR M5 FROM THE PCB
REMOVE TUBE FROM FRONT CONNECTOR OF APS

Next: p643, f623

INSPECTION AIR PRESSURE TUBE

Next: p644, !f645

INSPECTION AIR PRESSURE PIPE

REMOVE THE INNER COM

Next: p1514, !f647

INSPECTION FLUE

Next: !p648, !f649

OBSERVATION PUMP RUNS

Next: p699, f700

PUMP LIMPET

Next: p705, !f706

RESISTANCE THERMISTOR PRIMARY AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: p760, !f1512

TEMPERATURE DIFFERENTIAL DHW

FLOW RATE AT HOT TAP

Next: p1020, f710

OBSERVATION RUN APPLIANCE TO MAX TEMP

BOILER CH THERMOSTAT

Next: !p1477, ?715, ?717

RESISTANCE FAN AND HARNESS AND TO EARTH

REMOVE CONNECTOR M13 FROM THE PCB

Next: p723, f726

RESISTANCE GAS VALVE

REMOVE LEAD FROM GAS VALVE

Next: p1483, !f727

PRESSURE GAS MINIMUM ADJUSTMENT NOT IGNITING

REMOVE 1 WIRE FROM THE MODUREG AND MAKE SAFE
ATTACH U GAUGE TO BURNER PRESSURE TEST POINT

Next: p954, !f955

PRESSURE GAS MINIMUM ADJUSTMENT

REMOVE 1 WIRE FROM THE MODUREG AND MAKE SAFE
ATTACH U GAUGE TO BURNER PRESSURE TEST POINT

Next: p970, !f971

PRESSURE GAS MINIMUM ADJUSTMENT

REMOVE 1 WIRE FROM THE MODUREG AND MAKE SAFE
ATTACH U GAUGE TO BURNER PRESSURE TEST POINT

Next: p966, !f967

EXTERNAL BYPASS

Next: p707, !f772

VOLTAGE AC TO GAS VALVE AT PCB

{GAINPCBACS}

Next: p783, f776

RESISTANCE GAS VALVE

REMOVE LEAD FROM GAS VALVE

Next: p786, !f782

DIODE TEST HARNESS GAS VALVE

REMOVE THE CONNECTOR

Next: !p784, !f785

DIODE TEST HARNESS GAS VALVE

REMOVE THE CONNECTOR

Next: p1061, !f827

DIODE TEST HARNESS GAS VALVE

REMOVE THE CONNECTOR

Next: p1064, !f791

RESISTANCE OVERHEAT STATS AND HARNESS

REMOVE CONNECTOR M7 FROM THE PCB

Next: !p812, f813

RESISTANCE AIR PRESSURE SWITCH AND HARNESS AT REST

REMOVE CONNECTOR M5 FROM THE PCB

Next: !p817, f818

INSPECTION AIR PRESSURE TUBE

Next: !p823, !f824

RESISTANCE FUSE F2A

REMOVE THE FUSE FROM THE INCOMING MAINS TERMINAL STRIP

Next: !p867, f859

FURTHER INVESTIGATION LED FAULTY

TESTS SO FAR HAVE PR

Next: !p870, !f871

OBSERVATION WATER SUPPLY TO PREMISES

TURN ON A COLD WATER TAP

Next: p1163, !f91

RESISTANCE THERMISTOR PRIMARY AND HARNESS

REMOVE CONNECTOR M6 FROM THE PCB

Next: !p918, !f1504

PRESSURE BURNER MAXIMUM

ATTACH U GAUGE TO BU

Next: !p950, f1033

INSPECTION VENT TUBE GAS VALVE

Next: p259, !f982

PRESSURE GAS INLET

ATTACH U GAUGE TO INLET PRESSURE TEST POINT

Next: p985, !f986

PRESSURE GAS MINIMUM ADJUSTMENT NOT ESTABLISHING

REMOVE 1 WIRE FROM THE MODUREG AND MAKE SAFE
ATTACH U GAUGE TO BURNER PRESSURE TEST POINT

Next: p987, !f988

FAULT CODES

Next: !p117, !f118

PRESSURE GAS INLET

ATTACH U GAUGE TO INLET PRESSURE TEST POINT

Next: p996, !f997

PRESSURE GAS MINIMUM ADJUSTMENT

REMOVE 1 WIRE FROM THE MODUREG AND MAKE SAFE
ATTACH U GAUGE TO BURNER PRESSURE TEST POINT

Next: p998, !f999

System Information

  • Total Tests: 586
  • Sequence Logic: Decoded from encrypted .seq file
  • Navigation: Dynamic based on pass/fail results
  • Source: 4731307 GW SWIFTFLOW 100 SIT Control