Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector M12 from the PCB
Measurement:
Test 1:
Measure the resistance between pin 35 and 36 on connector M12.
Expect approximately 160 ohms or greater.
Test 2:
Measure the resistance between pin 35 and a suitable earth.
Expect a resistance of 1 Mohm or greater.
Are the resistances measured as expected?
Measure the resistance between pin 35 and 36 on connector M12.
Expect approximately 160 ohms or greater.
Test 2:
Measure the resistance between pin 35 and a suitable earth.
Expect a resistance of 1 Mohm or greater.
Are the resistances measured as expected?

Isolate as per TOPs P4
and refit as necessary