Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect the inline connector on the detection lead
Measurement:
Test 1:
Inspect the detection electrode for good condition, cleanliness, damaged ceramic, correct alignment as per the diagram shown and that there is a gap from tip of electrode to the burner of 5-6mm.
Test 2:
Measure the resistance from the tip of the detection electrode to the pin in the inline connector.
Expect continuity / zero resistance.
Is the electrode satisfactory and the resistance as expected?
Note:
This test is carried out with the electrode in situ but is shown removed for clarity.
Inspect the detection electrode for good condition, cleanliness, damaged ceramic, correct alignment as per the diagram shown and that there is a gap from tip of electrode to the burner of 5-6mm.
Test 2:
Measure the resistance from the tip of the detection electrode to the pin in the inline connector.
Expect continuity / zero resistance.
Is the electrode satisfactory and the resistance as expected?
Note:
This test is carried out with the electrode in situ but is shown removed for clarity.

Isolate as per TOPs P4
and refit as necessary