Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
Turn Hot Water Tap On
Attach U-gauge to gas valve inlet pressure test point
Selector switch to DHW position
CH temperature selector to minimum
DHW temperature selector to maximum
Gas On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow fan to start and ignition sequence to run.
Observe U-gauge. Does the inlet pressure remain constant at approximately 20 mb?
Note: When U-gauge is removed pressure Test Point should be tightened and checked for gas soundness.