Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the M1 connector from the PCB.
Measurement:
Test 1:
Measure the resistance across connections 14 (Black) and 13 (Blue) of the microswitch.
Expect open circuit.
Test 2:
Turn hot tap ON.
Measure the resistance across connections 14 (Black) and 13 (Blue) of the microswitch.
Expect continuity / zero resistance.
Measure the resistance across connections 14 (Black) and 13 (Blue) of the microswitch.
Expect open circuit.
Test 2:
Turn hot tap ON.
Measure the resistance across connections 14 (Black) and 13 (Blue) of the microswitch.
Expect continuity / zero resistance.

Isolate as per TOPs P4
and refit as necessary