Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Disconnect M5 from the PCB
Disconnect blue wire from the APS
Disconnect M5 from the PCB
Disconnect blue wire from the APS
Measurement:
Measure the resistance between pin 31 (Blue) of the disconnected M5 plug to the disconnected blue wire at the APS.
Resistance should be short circuit (zero resistance).
Inspect harness and connectors for good overall condition.
Resistance should be short circuit (zero resistance).
Inspect harness and connectors for good overall condition.

Isolate as per TOPs P4