Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the cover from the pump assembly
Remove the wires from the pump assembly
Remove the wires from the pump assembly
Measurement:
Test 1:
Measure the resistance between the live and neutral terminals of the pump assembly.
Expect approximately 160 ohms or greater.
Test 2:
Measure the resistance between the live and earth terminals of the pump assembly.
Resistance should be greater than 1M Ohm (or O.L.)
Are the resistances measured as expected?
Measure the resistance between the live and neutral terminals of the pump assembly.
Expect approximately 160 ohms or greater.
Test 2:
Measure the resistance between the live and earth terminals of the pump assembly.
Resistance should be greater than 1M Ohm (or O.L.)
Are the resistances measured as expected?

Isolate as per TOPs P4
and refit as necessary