Set Appliance State:

Mains Power Off
Selector switch to DHW & CH position
DHW temperature selector to maximum
Ensure no demands
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Reset appliance as necessary.
Boiler should enter standby and pump should not be running.
Turn Hot Water Tap ON with a flow rate of 3 l/min.
Does the pump now run?
Do not take sound or vibration as an indication of the pump running.