Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Attach U-gauge to burner pressure test point
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Allow burner to ignite and establish.
Is the maximum burner pressure 12.2mb +/- 0.5mb (N.G)?
Notes:
1. Maximum Propane: 36.2mb. Maximum Butane 28.3mb.
2. Burner pressure will ramp up during ignition sequence then may go down, allow burner to fully establish before checking burner pressure.
3. When pressure gauge is removed pressure test point should be tightened and checked for gas soundness.
Is the maximum burner pressure 12.2mb +/- 0.5mb (N.G)?
Notes:
1. Maximum Propane: 36.2mb. Maximum Butane 28.3mb.
2. Burner pressure will ramp up during ignition sequence then may go down, allow burner to fully establish before checking burner pressure.
3. When pressure gauge is removed pressure test point should be tightened and checked for gas soundness.