Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect inline connector to sprayaway pump
Disconnect X11 from the PCB
Disconnect X11 from the PCB
Measurement:
Check for continuity (zero resistance) between
both the brown and blue wires that run
between the pump and the PCB.
Inspect the harness and the plugs for good overall condition.
both the brown and blue wires that run
between the pump and the PCB.
Inspect the harness and the plugs for good overall condition.

Isolate as per TOPs P4
and refit as necessary