Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect wires from diverter valve
Unclip and remove diverter valve

Measurement:

Measure the resistance across the actuator terminals as per table below:
(Numbers are printed on the diverter motor)
Black test probeRed test probeResistance
215.9kOhms or open circuit
135.9kOhms or open circuit

Note:
For reassembly correct position of wires is:
White - 1, Black - 2, Red - 3