Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect inline connector at pump for mains voltage
Measurement:
Test 1:
Measure between the brown and blue wires at the disconnected plug.
Resistance should be greater than 1 MOhm.
Test 2:
Measure between the brown wire and the earth wire at the disconnected plug.
Resistance should be greater than 1 MOhm.
Measure between the brown and blue wires at the disconnected plug.
Resistance should be greater than 1 MOhm.
Test 2:
Measure between the brown wire and the earth wire at the disconnected plug.
Resistance should be greater than 1 MOhm.

Isolate as per TOPs P4
and refit as necessary