Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Gain access to PCB (use Insulation Mat as required)
Disconnect connector X4 at the PCB
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

If boiler is in lockout reset it then turn mains power OFF then back ON
so that it starts the appliance self check. (AP shown on display).
Measure the voltage from pins 4, 5 and 6 to pin 7 of X4
using the test points on the connector.
Voltages should be approximately as below:
TestExpected Voltage
Pin 4 to Pin 720V DC
Pin 5 to Pin 722V DC
Pin 6 to Pin 717V DC