Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector X11 from the PCB
Measurement:
Test 1:
Measure the resistance between the blue and brown wires on the right hand side of X11.
Resistance should be greater than 1 MOhm.
Test 2:
Measure the resistance between the brown wire to a suitable earth point.
Resistance should be greater than 1 MOhm.
Measure the resistance between the blue and brown wires on the right hand side of X11.
Resistance should be greater than 1 MOhm.
Test 2:
Measure the resistance between the brown wire to a suitable earth point.
Resistance should be greater than 1 MOhm.

Isolate as per TOPs P4
and refit as necessary