Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect inline connector at pump for mains voltage
Measurement:
Test 1:
Measure between the black wires at the disconnected plug.
Resistance should be approximately 220 Ohms.
(if an ErP pump is fitted resistance will be significantly higher)
Test 2:
Measure between one of the black wires to
the earth wire at the disconnected plug.
Resistance should be greater than 1M Ohm.
Measure between the black wires at the disconnected plug.
Resistance should be approximately 220 Ohms.
(if an ErP pump is fitted resistance will be significantly higher)
Test 2:
Measure between one of the black wires to
the earth wire at the disconnected plug.
Resistance should be greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary