Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
CH Demand
Attach temperate clamp to return pipe above pump as shown
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Enter service mode (hold tap & radiator buttons) then go to Settings > Special Function > Siphon fill Programme and turn off - remember to turn back on after test.
Press menu button (3 dashes) and select
boiler status to view flow temperature.
Allow boiler to operate on CH for at least 2 minutes.
Measure the differential between the flow temperature on the display and the return temperature on the FGA.
Differential should be approximately 25 degrees or less.
Note:
Do NOT attach a second probe to flow pipe to check differential.
This is due to an issue with the new FGA Click here for information.