Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Disconnect LV2 from the PCB and make safe
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the voltage between pins 14 and 15 at LV2 on the PCB during the appliances 15 second self-check period.
The voltage should be seen to fluctuate from 0 - 24 VDC
some multimeters may show 0 - O.L or a negative voltage due to their response time - this is acceptable as are any voltage fluctuations on the multimeter display)
Notes:
1. Turn off/on as necessary until test complete.
2. If you are unable to test with in the 15 second self-check period then then click here for an alternative test.