Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove mains connection from pump
Measurement:
Test 1:
Measure the resistance between the two outer pins of the pump mains connection.
Resistance should be greater than 1M Ohm (or O.L on meter).
Test 2:
Measure the resistance between the top two pins of the pump mains connection.
Resistance should be greater than 1M Ohm (or O.L on meter).
Are the resistances measured as expected?
Measure the resistance between the two outer pins of the pump mains connection.
Resistance should be greater than 1M Ohm (or O.L on meter).
Test 2:
Measure the resistance between the top two pins of the pump mains connection.
Resistance should be greater than 1M Ohm (or O.L on meter).
Are the resistances measured as expected?

Isolate as per TOPs P4
and refit as necessary