Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Remove diverter motor from its housing and place in a safe location to observe its movement
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Reset appliance as necessary.
Observe the diverter motor during the boiler's self-check.
The diverter spindle should slowly move to its fully extended position (if it is not there already).
Apply a CH demand.
The spindle should now move to its fully retracted position.
Note:
If you will not be able to observe the diverter movement within 15 seconds of turning the mains power on click here for an alternative test.