Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector from pump
Measurement:
Test 1:
Measure the resistance across the pump live (right) and the neutral (left) pin.
Expect greater than 1M Ohm.
Test 2:
Measure the resistance between the pump live (right) pin and the pump earth (middle) pin.
Expect greater than 1M Ohm.
Test 3:
Measure the resistance between the pump neutral (left) and the pump earth (middle) pin.
Expect greater than 1M Ohm.
Measure the resistance across the pump live (right) and the neutral (left) pin.
Expect greater than 1M Ohm.
Test 2:
Measure the resistance between the pump live (right) pin and the pump earth (middle) pin.
Expect greater than 1M Ohm.
Test 3:
Measure the resistance between the pump neutral (left) and the pump earth (middle) pin.
Expect greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary