Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
DHW flow rate greater than 3 ltr/min
DHW flow rate greater than 3 ltr/min
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure DC voltage across pin 6 (yellow wire) connector LV2 and a suitable earth connection.
Expected voltage should be between 2.0 - 3.0 VDC.
Expected voltage should be between 2.0 - 3.0 VDC.