Set Appliance State:
Mains Power Off
CH Demand
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Reset appliance as necessary and allow the boiler to complete its self check.
Set the boiler into service mode by holding the       button for approx. 5 seconds.
Switch between maximum and minimum rate by using the DHW up and down arrows.
To exit service mode press the       button once.
Carry out a combustion check at both maximum and minimum rates as per manufacturer's instructions
(refer to Adapt for more guidance).
Is the appliance within CO and CO² tolerances on both maximum and minimum rate?
Set the boiler into service mode by holding the       button for approx. 5 seconds.
Switch between maximum and minimum rate by using the DHW up and down arrows.
To exit service mode press the       button once.
Carry out a combustion check at both maximum and minimum rates as per manufacturer's instructions
(refer to Adapt for more guidance).
Is the appliance within CO and CO² tolerances on both maximum and minimum rate?