Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Disconnect connector LV2 at the PCB
Disconnect connector LV2 at the PCB
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Does the display now operate?
(A fault code may be displayed)
(A fault code may be displayed)
Isolate as per TOPs P4
and refit as necessary