Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Disconnect the lead from the flame sense electrode
(the front electrode of the three electrodes)
Disconnect the lead from the flame sense electrode
(the front electrode of the three electrodes)
Measurement:
Measure the resistance between the disconnected lead and the green wire on X5 marked 11.1.
Short circuit (zero resistance) expected.
Short circuit (zero resistance) expected.

Isolate as per TOPs P4
and refit as necessary