If appliance is in lockout it will not be possible to access test modes.
It could be up to 10 seconds after the button is pressed before the selected component responds.
| Test Number | Test Type | Description |
| t1 | Spark test | Spark generator will be switched on for 30 seconds |
| t2 | Fan test | Fan will run at maximum for 45 seconds |
| t3 | Pump test | Pump will run at maximum for 45 seconds |
| t4 | Diverter Motor test | When 1 is selected the motor will move to the DHW position (fully retracted), when 0 is selected it will move to the CH position (fully extended), |
| t6 | Ionisation voltage test | Ionisation / rectification circuit activated for 30 seconds |
To exit test mode press the spanner button twice, this may be done while the test is being carried out
The appliance has several "test" modes available to check the functionality of various components within the appliance.