FAULT CODES
None
Fault Code Reference - Model 4740648
| Status | Description | Additional Information |
|---|---|---|
| H11 | DHW sensor short or open circuit | Given no other faults, boiler will still operate using the primary flow and return sensors to modulate the DHW |
| H13 | Service Due | |
| 200 | CH system is being heated | Boiler has ignited, established and is running for a central heating demand |
| 201 | DHW system is being heated | Boiler has ignited, established and is running for a hot water or preheat demand |
| 202 | Anti rapid cycle mode | Central heating demand removed and then reinstated within the anti-cycle time set in 2.3B (default 10 minutes) |
| 203 | System stand by | Boiler has completed its self check and currently has no demand for heating, preheat or hot water |
| 204 | System waiting, primary flow temperature above setpoint | System is running for heating or hot water but primary flow sensor above 80°c for DHW or above the temperature setting for CH |
| 205 | Waiting for airflow | |
| 207 | System pressure too low | |
| 208 | Test mode active due chimney switch | Service mode activated (either on maximum or minimum) |
| 210 | Flue stat activated | Flue overheat thermostat has gone open circuit |
| 211 | TTB opened (thermal kickback device) | |
| 212 | Safety or flow temperature rises too fast | Safety or flow sensor has measured water temperature increase of over 5°C a second |
| 213 | Temperature difference between supply and return exceeding limit | |
| 214 | Fan not running | Signal from fan hall sensor not being sent or received |
| 215 | Fan running too fast | |
| 216 | Fan running too slow | |
| 217 | No Airflow after defined period of time | |
| 218 | Flow temperature too high | Flow sensor reading above 110°C |
| 219 | Safety sensor temperature too high | Safety sensor reading above 110°C |
| 220 | Safety sensor shorted | Safety sensor short circuit or very low resistance |
| 221 | Safety sensor disconnected | Safety sensor open circuit or very high resistance |
| 222 | Flow sensor shorted | Flow sensor short or very low resistance |
| 223 | Flow sensor disconnected | Flow sensor open circuit or very high resistance |
| 224 | MAX thermostat activated | |
| 225 | Difference between flow and safety exceeding limit (bi-sensor only) | |
| 227 | No ionisation detected after ignition | Burner not igniting or igniting and not rectifying |
| 228 | Ionisation current detected before burner-start | |
| 229 | Loss of ionisation signal during operation | Burner cutting out or losing rectification during demand |
| 230 | Ionisation signal out of bounds | |
| 231 | Mains power error - electrical power interruption | Mains power turned off to appliance whilst in lockout |
| 232 | external cut-off switch activated | |
| 233 | HCM problem | Code plug missing or faulty |
| 234 | Gas valve coil disconnected | One or both gas valve solenoids high resistance or open circuit |
| 237 | Airflow present during last 24 hours - fan running continuously | |
| 238 | Gas valve error | Gas valve shorting to earth or gas valve solenoid went open circuit / high resistance whilst appliance lit |
| 239 | Watchdog relay error | |
| 240 | Return sensor shorted | |
| 241 | Return sensor disconnected | |
| 242 | Internal error | |
| 243 | Internal error | |
| 244 | Internal error | |
| 245 | Internal error | |
| 246 | Internal error | |
| 247 | Internal error | |
| 248 | Internal error | |
| 249 | Internal error | |
| 250 | Internal error | |
| 251 | Internal error | |
| 252 | Internal error | |
| 253 | Internal error | |
| 254 | Internal error | |
| 255 | Internal error | |
| 256 | Internal error | |
| 257 | Internal error - replace control board | |
| 258 | Internal error | |
| 258 | Low mains power supply | Incoming voltage below 170V AC |
| 259 | Internal error | |
| 260 | No temperature rise after burner start | Burner has ignited and rectified but flow temperature has not increased |
| 261 | First safety timing error | |
| 262 | Internal error | |
| 263 | Internal error | |
| 264 | Airflow stopped during operation | |
| 265 | Stand-by mode forced due to energy transfer limit | |
| 266 | No pressure variation detected after switching pump | |
| 267 | Watchdog timeout error | |
| 268 | Component test mode | Shown whilst test t1-t6 is active |
| 269 | Ignition device activated too long | |
| 270 | Power up mode | Shown whilst appliance is completing its self check |
| 271 | Temperature difference between flow and safety sensor exceeding limit | Temperature difference between the flow and safety sensor whilst boiler was lit is greater than 15°C |
| 272 | Internal error | |
| 273 | Airflow present during last 24 hours | |
| 274 | Ionisation signal present during last 24 hours | |
| 276 | Flow temperature exceeded 95°C | |
| 277 | Safety sensor temperature exceeded 95°C | |
| 278 | Sensor test failed | |
| 279 | AD converter error, unstable measurement | |
| 280 | Recycle timing error | |
| 281 | Pump stuck or running in air | |
| 282 | No feedback from pump | |
| 283 | Burner starting | Shown as boiler is beginning sparking stage of ignition sequence |
| 284 | Gas valve(s) opened, first safety time started | Shown during the ignition sequence, appliance is now sending voltage to the gas valve |
| 285 | Return temperature exceeded 95°c | This will not go to a lockout condition unless the temperature remains over 95°c for 5 minutes or longer |
| 286 | Return temperature too high | This will not go to a lockout condition unless the temperature remains over 95°c for 5 minutes or longer |
| 287 | Ionisation sensor shorted | |
| 288 | Water pressure sensor not connected or short-circuit to supply | |
| 289 | Water pressure sensor not connected or short-circuit to ground | |
| 290 | AD converter reference error | |
| 305 | Anti fast cycle mode | Short anti purge mode after a DHW demand has ended |
| 306 | Ionisation detected after burner stop | Flame detected after demand ended |
| 307 | Pump stuck | |
| 308 | Pump running in air | |
| 309 | CH & DHW system are being heated | |
| 310 | CUS communication error | |
| 311 | CUS locked | |
| 312 | CUS blocked | |
| 313 | CUS reported error condition | |
| 314 | Mains disconnected during super lockout | Mains power turned off while appliance was in status 373 or 374 |
| 315 | Several times lack of water flow | |
| 316 | Flue gas sensor temperature too high | |
| 317 | Flue gas sensor shorted | |
| 318 | Flue gas sensor disconnected | |
| 321 | Self-test of flue gas supervision | |
| 322 | Code error | |
| 323 | EMS communication error | |
| 324 | DHW-NTC defect | DHW sensor resistance not stable |
| 325 | DHW-NTC not correctly installed | |
| 326 | Storage-NTC defect | |
| 327 | Reset-key stuck or short-circuit | |
| 328 | Internal error | |
| 329 | No pressure variation detected after switching pump | |
| 332 | Supply sensor exceeded 110°C | Flow sensor greater than 110°C |
| 333 | Start temporarily not allowed due to flow error on CH | Flow sensor resistance not stable |
| 338 | Too many short burner starts without confirmation of water flow | |
| 341 | CH: supply and/or return temperatures rising too fast | Whilst appliance is lit it has detected flow or return sensor temperature increasing by 5°c a second or more |
| 342 | HW: supply temperature rising too fast | Whilst appliance is lit it has detected flow sensor temperature increasing by 5°c a second or more |
| 343 | CH: flue gas temperature rising but supply temperature not | |
| 344 | HW: flue gas temperature rising but supply temperature not | |
| 345 | Supply and/or return temperatures do not change after burner start | |
| 346 | Flue gas temperature rising too fast | |
| 347 | Return temperature higher than supply temperature (some time after burner start) | |
| 348 | HW: supply temperature too hot | |
| 349 | CH: Boil Detect, large delta T despite minimum burner load | The boiler is operating at minimum burner load and the temperature difference between the flow and return sensors is greater than 18°C |
| 350 | Flow sensor shorted | |
| 351 | Flow sensor disconnected | |
| 353 | Burn temporarily blocked due to no 20 minute continuous OFF time in last 24 hours | |
| 354 | Overpressure setting erased | |
| 356 | Low mains power supply | Incoming voltage below 170V AC |
| 357 | Primary Heat Exchanger air venting program active - approx. 100 seconds | Setting 2.2C in parameters set to 1 in last 100 seconds |
| 358 | Three way valve kick | Displayed briefly as diverter valve changes position |
| 359 | DHW outlet temperature too hot | |
| 360 | HCM problem | Incorrect code plug fitted or code plug faulty. Also displays if PCB has been fitted to a different appliance previously. |
| 364 | Gas valve EV2 leak test failed | |
| 365 | Gas valve EV1 leak test failed | |
| 372 | Temporarily ignoring CH requests to limit temperatures of the appliance components | |
| 373 | SuperLock caused by too frequent thermostat overheat detections during burning | |
| 374 | SuperLock caused by too frequent ionisation loss during burning | |
| 375 | Preheat sensor on DHW inlet Short Circuit | Resistance of preheat sensor short circuit or very low resistance |
| 376 | Preheat sensor on DHW Inlet Open Circuit | As this sensor is optional this will only display if the sensor resistance was not open circuit during the appliance self check but has then gone open circuit or very high resistance |
| 380 | Inlet temperature greater than DHW Outlet Set point | |
| 800 | Outdoor sensor defect | |
| 808 | Domestic hot water sensor defect | |
| 810 | Domestic hot water remains cold | |
| 828 | Water pressure sensor defect |