Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure voltage between the black pin marked 15.2
and the yellow pin marked 15.3 on X5 connector at the PCB.
Voltage should be approximately 2.5V DC.
Notes:
This test can be carried out while the boiler is
completing its self check.
At flow rates below 3 litres a minute you may see
the voltage vary between 2V DC and 3V DC.