Set Appliance State:
Gas Off
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
NOT CURRENTLY USED
NOT CURRENTLY USED
NOT CURRENTLY USED
NOT CURRENTLY USED
Attach a crocodile clip to the rectification lead
NOT CURRENTLY USED
NOT CURRENTLY USED
NOT CURRENTLY USED
NOT CURRENTLY USED
Attach a crocodile clip to the rectification lead
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Reset appliance as necessary and allow boiler to complete its self check.
Once appliance begins ignition sequence,
measure the voltage between the green wire
on X4 marked 11.1 and the crocodile clip.
Approx 40V AC should be measured.
Less than 30V AC measured
Approx 40V AC measured
Approx 90V AC measured
Once appliance begins ignition sequence,
measure the voltage between the green wire
on X4 marked 11.1 and the crocodile clip.
Approx 40V AC should be measured.
Less than 30V AC measured
Approx 40V AC measured
Approx 90V AC measured