Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove ST9 connector from the PCB
If available use the Worcester test PCB to assist the resistance test

Measurement:

Test 1:
Measure the resistance between the two black wires
terminal 3 and 4 counting from left to right.
Then measure between the two black wires at
terminal 5 and 6 counting from left to right.
Expect approximately 177 ohms on one pair
of black wires and 400 ohms on the other pair.
Test 2:
Measure the resistance between each
of the black wires 3,4,5 and 6 to earth.
Expect open circuit on each test