Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove ST9 connector from the PCB
If available use the Worcester test PCB to assist resistance test
If available use the Worcester test PCB to assist resistance test
Measurement:
Test 1: Measure the resistance between the two black wires
terminal 3 and 4 counting from left to right.
Expect approximately 165 ohms
Test 2: Measure the resistance between the two black wires
terminals 5 and 6 counting from left to right.
Expect approximately 165 ohms
Test 3: Measure the resistance between
each of the black wires 3,4,5 and 6 to earth.
Expect open circuit on each test
Note:
The colours of the wires may vary
but the terminal locations will remain the same.
terminal 3 and 4 counting from left to right.
Expect approximately 165 ohms
Test 2: Measure the resistance between the two black wires
terminals 5 and 6 counting from left to right.
Expect approximately 165 ohms
Test 3: Measure the resistance between
each of the black wires 3,4,5 and 6 to earth.
Expect open circuit on each test
Note:
The colours of the wires may vary
but the terminal locations will remain the same.

Isolate as per TOPs P4
and refit as necessary