Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove the 20 way connector from the PCB
Ensure primary heat exchanger is below 60° C

Measurement:

Measure resistance across the right hand pair of orange wires terminals 19 & 20 counting left to right.
The resistance should conform to the table below:
Temperature °CResistance in kOhms
20-308.0-16.0
30-40 6.0-10.0
40-503.9-8.0
50-602.5-5.5
60-701.5-3.0

Refit connector after test.
Note:
The colours of the wires may vary but the terminal locations will remain the same.