Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove pump connector from PCB
Measurement:
Test 1:
Measure the resistance between the brown and blue wires at the disconnected connector.
Expect approximately 11.4 kOhms or greater.
Test 2:
Measure the resistance between the blue and earth.
Expect a resistance of 1MOhm or greater.
(O.L is acceptable because this is greater than 1MOhm)
Test 3:
Measure the resistance between brown and earth.
Expect a resistance of 1MOhm or greater.
(O.L is acceptable because this is greater than 1MOhm)
Measure the resistance between the brown and blue wires at the disconnected connector.
Expect approximately 11.4 kOhms or greater.
Test 2:
Measure the resistance between the blue and earth.
Expect a resistance of 1MOhm or greater.
(O.L is acceptable because this is greater than 1MOhm)
Test 3:
Measure the resistance between brown and earth.
Expect a resistance of 1MOhm or greater.
(O.L is acceptable because this is greater than 1MOhm)

Isolate as per TOPs P4
and refit as necessary